From: Jim O'Connor <oconnor.jim77**At_Symbol_Here**GMAIL.COM>
Subject: Re: [DCHAS-L] Dichloromethane storage?
Date: Fri, 11 Apr 2014 14:57:53 -0400
Reply-To: DCHAS-L <DCHAS-L**At_Symbol_Here**MED.CORNELL.EDU>
Message-ID: 38A13903-280F-403E-8278-1EE32CD2AABB**At_Symbol_Here**gmail.com
In-Reply-To


Sigma Aldrich has a SDS that says, "Heat sensitive. Store under inert gas" I don't agree with that statement but thought you should know about the ref. My experience says the inert gas recommendation is to prevent it from evaporating while storing. A liquid seal cap should negate the need for the inert gas too I think.

Sent from my iPhone

> On Apr 11, 2014, at 12:39 PM, "Ralph B. Stuart" wrote:
>
> A lab tech noticed a statement on a Dichloromethane bottle that said "store under an inert gas". He would like to know if this is a safety recommendation or designed to maintain the quality of the chemical by avoiding exposure to environmental gases. From what I can find, it appears to be the latter, but I thought I would ask DCHAS-L to see if anyone knows of a safety reason for this recommendation.
>
> Thanks for any help with this.
>
> - Ralph
>
>
> Ralph Stuart CIH
> Chemical Hygiene Officer
> Department of Environmental Health and Safety
> Cornell University
>
> rstuart**At_Symbol_Here**cornell.edu

Previous post   |  Top of Page   |   Next post



The content of this page reflects the personal opinion(s) of the author(s) only, not the American Chemical Society, ILPI, Safety Emporium, or any other party. Use of any information on this page is at the reader's own risk. Unauthorized reproduction of these materials is prohibited. Send questions/comments about the archive to secretary@dchas.org.