That says the wrong engineer installed or designed the system.  If the ducts were round with no right angle bends, and were sized for a 4000 l/m centerline velocity as ACGIH recommends, there would be no deposition. A lot of these desk-sized systems available off-the-shelf are not even close to good design.   Monona

In a message dated 9/21/2010 9:19:27 AM Eastern Daylight Time, kauletta**At_Symbol_Here**NOTES.CC.SUNYSB.EDU writes:


The biggest problem I had with silica control in our dental school was cleaning out the local ventilation system. I had them get the small HEPA vacuum (the real kind) and that made a big improvement.

Kim Auletta
Lab Safety Specialist
EH&S    Z=3D6200
Stony Brook University
kauletta**At_Symbol_Here**notes.cc.sunysb.edu
631-632-3032
EH&S Web site: http://www.stonybrook.edu/ehs/lab/

Previous post   |  Top of Page   |   Next post



The content of this page reflects the personal opinion(s) of the author(s) only, not the American Chemical Society, ILPI, Safety Emporium, or any other party. Use of any information on this page is at the reader's own risk. Unauthorized reproduction of these materials is prohibited. Send questions/comments about the archive to secretary@dchas.org.